Mechanical Properties and Microstructure of the Leucite-Reinforced Glass-Ceramics for Dental CAD/CAM
J Dent Hyg Sci 2018;18:42-9
Published online February 28, 2018;  https://doi.org/10.17135/jdhs.2018.18.1.42
© 2018 Korean Society of Dental Hygiene Science.

Seon-Mi Byeon, and Jae-Joo Song1,†

Dental Clinic of Ebarun, Suncheon 57997, Korea
Correspondence to: Jae-Joo Song Department of Dental Hygiene, Cheongam College, 1641 Noksaek-ro, Suncheon 57997, Korea Tel: +82-61-740-7312, Fax: +82-61-740-7312, E-mail: profesong@daum.net
Received December 22, 2017; Revised January 12, 2018; Accepted January 17, 2018.
This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Abstract

The computer-aided design/computer-aided manufacturing (CAD/CAM) system was introduced to shorten the production time of all-ceramic restorations and the number of patient visits. Among these types of ceramic for dental CAD/CAM, they have been processed into inlay, onlay, and crown shapes using leucite-reinforced glass-ceramics to improve strength. The purpose of this study was to observe the mechanical properties and microstructure of leucite-reinforced glass-ceramics for dental CAD/CAM. Two types of leucite-reinforced glass-ceramic blocks (IPS Empress CAD, Rosetta BM) were prepared with diameter of 13 mm and thickness of 1 mm. Biaxial flexural testing was conducted using a piston-on-three-ball method at a crosshead speed of 0.5 mm/min. Weibull statistics were used for the analysis of biaxial flexural strength. Fracture toughness was obtained using an indentation fracture method. Specimens were observed by field emission scanning electron microscopy to examine the microstructure of the leucite crystalline phase after acid etching with 0.5% hydrofluoric acid aqueous solution for 1 minute. The results of strength testing showed that IPS Empress CAD had a mean value of 158.1±8.6 MPa and Rosetta BM of 172.3±8.3 MPa. The fracture toughness results showed that IPS Empress CAD had a mean value of 1.28±0.19 MPa·m1/2 and Rosetta BM of 1.38±0.12 MPa·m1/2. The Rosetta BM sample exhibited higher strength and fracture toughness. Moreover, the crystalline phase size and ratio were increased in the Rosetta BM sample. The above results are expected to elucidate the basic mechanical properties and crystal structure characteristics of IPS Empress CAD and Rosetta BM. Additionally, they will help develop leucite-reinforced glass-ceramic materials for CAD/CAM.

Keywords : Biaxial flexural strength, CAD/CAM, Fracture toughness, Leucite-reinforced glass-ceramic, Microstructure
Introduction

Dental ceramics are excellent dental restoration materials due to their excellent durability and esthetics, but they are susceptible to brittle fracture at a relatively low level of stress1). To improve their strength and sensitivity to brittle fracture, metal-ceramic restorations, with metal as the core material, are being widely used. However, they are vulnerable to problems such as increased opacity, exposed metal in the margins due to gingival recession, low bonding strength between metal and ceramic, and metal allergy. Consequently, there is heightened interest in all-ceramic restorations that can offer aesthetics, marginal integrity, and fracture resistance2,3).

In the early 1980s, Adair and Grossman found a way to improve all-ceramic system from crystallization by controlling glass, and since then, various types of glass-ceramic have been developed4,5). Glass-ceramic materials have excellent biocompatibility and improved strength over regular glass, while also satisfying the esthetic demands of both clinicians and patients.

Among them, leucite-reinforced glass-ceramic (LRGC), which contains potassium-aluminum-silicate (KAlSi2O6) crystalline mineral leucite within a glass matrix, allows the thermal expansion coefficient of glass-ceramic to be controlled according to the content of leucite crystals, which have high thermal expansion (>20×20−6/°C). Moreover, it can increase the strength of glass-ceramic by absorbing the fracture energy to delay or suppress the propagation of cracking6,7). With increasing demand for restorations with natural tooth color, LRGC with excellent esthetics is being used as the material for all-ceramic restorations8).

Meanwhile, the computer-aided design and computer- aided manufacturing (CAD/CAM) method have been introduced to shorten the time required to fabricate all-ceramic restorations and reduce the number of patient visits. CAD/CAM for fabrication of dental restorations was developed in the 1980s, and has evolved since then with improvements in hardware, software, and CAD/CAM materials, and as a result, its clinical application has gained much popularity9). Machinable ceramic blocks can be fabricated into different shapes using the CAD/CAM system, including inlays, onlays, and crowns. For fabrication of the restoration, the missing tooth is scanned and imaged through a computer, after which, the restoration is fabricated into the desired shape by a milling machine according to computer-controlled input. The disadvantages of such CAD/CAM restorations include imprecise fitting inside the mouth and the fabrication process being technically sensitive, and requiring expensive equipment6). On the other hand, their main advantages include the fact that they do not require impression taking, which can shorten treatment time and reduce the need for materials related to the impression process, while also reducing the number of patient visits, which can result in increased satisfaction level in the patients and clinicians10).

Along with the development of LRGC materials machinable through the CAD/CAM method, measurements of their elastic modulus, flexural strength, surface hardness, and fracture toughness are being performed to assess their physical properties. Typically, flexural strength indicates how well glass-ceramic, a brittle material, fares inside the mouth, while fracture toughness measures the sensitivity of glass-ceramic, which is strongly affected by defects11,12).

Accordingly, the objective of the present study was to measure the biaxial flexural strength and fracture toughness of two types of LRGC material for CAD/CAM application, IPS Empress CAD (Ivoclar Vivadent, Schaan, Liechtenstein) and Rosetta BM (HASS, Gangneung, Korea), and to observe the microstructures of their crystals to identify their basic physical properties.

Materials and Methods

1. Materials

The two types of LRGC block for CAD/CAM application used in the present study were IPS Empress CAD and Rosetta BM (Table 1).

Leucite-Reinforced Glass-Ceramic Blocks for Dental CAD/CAM Used in This Study

Product nameManufacturer
IPS Empress CAD Ivoclar Vivadent (Schaan, Liechtenstein) 
Rosetta BMHASS (Gangneung, Korea)

2. Methods

1) Biaxial flexural strength measurement

Millable blocks were cut to prepare 15 specimens of each type, with each disk-shaped specimen having a diameter of 13.0 mm and thickness of 1.0 mm. After initially polishing both surfaces of the specimens with #400∼1,200 SiC sand paper, the final polishing was performed using diamond slurry (Buehler, Lake Bluff, IL, USA), 1 μm in size, to remove the polishing marks from the surface where the tensile load would be applied.

Using the polished disk-shaped specimens, biaxial flexural strength was measured in 15 specimens from each experimental group, in accordance with ISO 6872. The loading device for biaxial flexural strength testing was fixed on a universal testing machine (model 4201; Instron, Canton, MA, USA); a specimen holding device with a circumference maintaining a diameter of 10 mm and having steel balls (1.5 mm in diameter) placed 120° apart was loaded on the machine. Subsequently, a piston (1.6 mm in diameter) was used to apply compressive force at a load speed of 0.5 mm/min. A polyethylene film was placed between the piston and the disk-shaped specimen to ensure that the load was applied evenly, and the load at the moment of fracture was measured (Fig. 1). The biaxial flexural strength was calculated using the following equation (σ)13). The mean value for each experimental group was derived, and the final value was calculated accordingly.

σ=0.2387P(X-Y_/b2X=(1+v)ln(r2/r3)2+{(1v)/2}(r2/r3)2Y=(1+v){1+ln(r1/r3)2}+(1v)(r1/r3)2

σ : maximum flexural strength (MPa)

P: fracture load (N)

B: specimen thickness (mm)

v: Poisson’s ratio (set to 0.25)

r1: support radius (mm)

r2: circumferential radius of loading area (mm)

r3: specimen radius (mm)

Fig. 1.

(A) Biaxial flexural test device. (B) Schematic illustration of the piston-on-three ball biaxial flexural test (unit: mm).


A statistical analysis is required when analyzing the fracture strength of brittle materials, which is highly sensitive to defects. Consequently, Weibull analysis was performed using OriginPro 8 (OriginLab, Northamton, MA, USA).

2) Fracture toughness measurement

For fracture toughness measurements, the Vickers indentation fracture (IF) method was used. For each experimental group, 15 Vickers indenters were fixed on a micro Vickers hardness tester (HM-124; Mitutoyo, Tokyo, Japan) and indentations were formed under the conditions of holding time 15 seconds and indentation load 9.8 N. The experiment was conducted under room temperature of 23±1°C and relative humidity of 50±10%, and to minimize measurement errors, the initial crack length (ICL) was measured within 5 minutes from forming the indentation. Ultimately, the following equation was used to calculate the fracture toughness value14,15). The mean value for each experimental group was derived, and the final value was calculated accordingly.

Kc=0.016(E/H)1/2(P/C3/2)H=0.4635P/a2

Kc: fracture toughness value (Pa.m1/2)

E: elastic modulus (Pa)

H: Vickers hardness (Pa)

P: indentation load (N)

C0: ICL (m)

a: half-length of indentation diagonal (m)

For the values of E, elastic modulus, the values provided by the manufacturers (IPS Empress CAD: 62 GPa, Rosetta BM: 90 GPa) were used.

3) Structural observation

For identification of leucite crystalline microstructures after surface polishing, observations were performed using a field emission scanning electron microscope (S800; Hitachi, Tokyo, Japan) after 1 minute of acid etching in aqueous 0.5% hydrofluoric acid (HF) solution. Moreover, indentation created by fracturing the Vickers indenter was observed using an optical microscope (DM 2500; Leica Microsystem, Wetzlar, Germany).

4) Statistical analysis

Statistical analysis was performed on the measured values using SPSS 12.0 (SPSS Inc., Chicago, IL, USA). One-way ANOVA was performed for significance testing, and for variables that showed significant differences, post-hoc testing was performed by Tukey’s test (p=0.05).

Results

1. Measurement results on biaxial flexural strength of veneering ceramic

Fig. 2 shows the flexural strength measurement results. LRGC materials IPS Empress CAD and Rosetta BM had mean values of 158.1±8.6 MPa and 172.3±8.3 MPa, respectively, where Rosetta BM had a significantly higher value (p<0.05).

Fig. 2.

Biaxial flexural strength of the two leucite-reinforced glass-ceramics for dental computer-aided design/computer- aided manufacturing (CAD/CAM) (IPS Empress CAD, Rosetta BM) (n=15).


Fig. 3 shows the Weibull analysis results on flexural strength. The table within the figure shows the values that demonstrate the distribution characteristics. Weibull distribution tended to show good consistency in single mode (r2>0.968), Weibull coefficient (m) and characteristic strength (σ0) were higher in Rosetta BM than in IPS Empress CAD.

Fig. 3.

Weibull analysis of the biaxial flexural strength


2. Fracture toughness measurement results

Fig. 4 shows the results of observations using optical microscopy after fracturing of Vickers indenters by applying an indentation load of 9.8 N (1 kg). In the IF area, indentation mark on the Vickers indenter and radial crack growing in diagonal direction from the indentation were observed.

Fig. 4.

Vickers produced indentation crack pattern of the two leucite-reinforced glass-ceramics; (A) IPS Empress CAD, (B) Rosetta BM. Scale bars=50 μm.


Fig. 5 shows the fracture toughness values derived by the Vickers IF method, where Rosetta BM (1.38±0.12 MPa·m1/2) had a significantly higher value than IPS Empress CAD (1.28±0.19 MPa·m1/2; p<0.05).

Fig. 5.

Fracture toughness of the two leucite-reinforced glass- ceramics for dental computer-aided design/computer-aided manufacturing (CAD/CAM) (IPS Empress CAD, Rosetta BM) (n=15).


3. Structural observation results

Fig. 6 shows the microstructure images of IPS Empress CAD (Fig. 6A) and Rosetta BM (Fig. 6C), where glassy matrix and leucite crystals were observed. Because of treatment with 0.5% HF for microstructure observations, leucite crystals were dissolved before the glassy matrix and they were distributed along the boundaries of those crystals. The leucite crystals of IPS Empress CAD were evenly and densely distributed at a volume of 35∼45%. Moreover, the crystal size varied with a range of 1∼5 μm, while formation of small beads appeared as well (Fig. 6B). Rosetta BM also showed similar crystalline patterns, but the size and ratio were higher than that of IPS Empress CAD (Fig. 6D).

Fig. 6.

Microstructure of leucite- reinforced glass-ceramics for dental computer-aided design/computer- aided manufacturing (CAD/CAM), which was etched with 0.5% hydrofluoric acid for 60 seconds (field emission scanning electron microscope images). (A) IPS Empress CAD (×500), (B) IPS Empress CAD (×5,000), (C) Rosetta BM (×500), (D) Rosetta BM (×5,000). GM: glassy matrix, LC: leucite crystal.


Discussion

Early use of dental CAD/CAM was limited to just ceramic inlays, but in recent times, its range of use has expanded to include veneers, all-ceramic crowns, and ceramic frameworks9,16,17). Consequently, advances in dental CAD/CAM technology have had a major impact on the clinical utilization of glass-ceramic materials, which has also resulted in major advancement in all-ceramic prostheses through the ability to use a diverse range of materials18). In particular, LRGC materials have been commercialized as CAD/CAM ceramic blocks and their range of use has become diversified in various clinical cases to include veneers, inlays, onlays, and anterior and posterior crowns19,20). In addition, the overall flexural strength of LRGC (73∼182 MPa) is higher than that of traditional feldspathic porcelain (55∼87 MPa), while the ability to fabricate ceramic crowns with excellent fracture resistance and marginal integrity has been greatly enhanced20,21).

Methods that measure the flexural strength and fracture toughness of dental glass-ceramic materials are used to assess their mechanical properties. Among the methods for measuring flexural strength, biaxial flexural strength measurement is used to examine the fracture characteristics of ceramic materials, where the piston-on-three- balls method recommended by ISO 6872 is generally used22,23). Meanwhile, fracture toughness measurement methods include single edge precracked beam, compliance, and IF methods14). Among them, the IF method is often used, as it involves a simple measurement method and there are no constraints due to the shape and appearance of the specimen, while allowing repeated measurements from a single small specimen24).

To examine the fracture characteristics of IPS Empress CAD and Rosetta BM, two types of LRGC material used in CAD/CAM restorations, which were the test materials in the present study, the biaxial flexural strength of these materials was measured. Moreover, the IF method was applied to derive the indentation load and ICL, after which fracture toughness was measured.

Experimental results showed that the biaxial flexural strength of IPS Empress CAD and Rosetta BM was 158.1±8.6 MPa and 172.3±8.3 MPa, respectively, where Rosetta BM had a significantly higher value (Fig. 2). Among papers that showed similar results, Ritzberger et al.2) reported that the biaxial flexural strength of IPS Empress CAD was 160 MPa.

After measuring the flexural strength, Weibull analysis was performed on the brittle materials, which are sensitive to defects. Ceramic materials with higher Weibull coefficient (m) values can be viewed as materials with higher structural stability, and materials with relatively high Weibull coefficient (m≥20) can be considered to have a small range of error and high clinical reliability22,25,26). In the Weibull analysis, IPS Empress CAD and Rosetta BM showed 20.25 and 23.21, respectively (Fig. 3). Therefore, the two materials showed biaxial flexural strength values with small range of error and high clinical reliability, where Rosetta BM can be viewed as the ceramic material with greater structural stability. However, for more accurate comparison of structural stability between different materials, other factors such as strength level and fracture toughness must be considered together27). The fracture toughness results in the present study showed that IPS Empress CAD had a value of 1.28±0.19 MPa·m1/2 and Rosetta BM had a higher value of 1.38±0.12 MPa·m1/2 (Fig. 5). Such results were similar to the fracture toughness value of IPS Empress CAD (1.3 MPa·m1/2) reported by Ritzberger et al.2) through measurement by the IF method.

Leucite glass-ceramics consist of a glass phase and a crystal (inorganic) phase. The glass phase has the typical characteristics of glass, such as brittleness, non-directional fracture pattern, transparency, and high surface tension in the liquid state. The crystal phase consists of leucite (potassium aluminosilicate) with high thermal expansion (>20×20−6/°C), where the thermal expansion coefficient of ceramic can be controlled by the amount present, which can contribute to the strength6). The images of microstructures of LRGC used in the present study showed a glassy matrix and leucite crystals (Fig. 6), where Rosetta BM showed higher leucite crystal content than IPS Empress CAD, which was consistent with literature reporting that it has an impact on increase in strength6). Moreover, Della Bona et al.28) also reported that greater amount and bigger size of leucite crystals in leucite ceramics can increase the fracture toughness of the materials, which can increase their strength.

The present study used LRGC materials, where the mechanical characteristics of recently developed Rosetta BM were identified by comparison to the previously developed IPS Empress CAD. As a result, clinically reliable values were obtained. In particular, Rosetta BM showed excellent biaxial flexural strength and fracture toughness, factors that have a major impact on the clinical applicability of the material being used, and together with the results of IPS Empress CAD, the findings in the present study may be used as basic information in the development of LRGC material for CAD/CAM restorations and material selection during prostheses fabrication.

The limitations of the present study were as follows. First, when prostheses are fabricated with ceramic material, the success of the prostheses depends on numerous factors including the moisture environment inside the mouth and fatigue. Second, flexural strength measurements may be affected by various factors, such as the specimen polishing process, load speed, and the area of the specimen receiving the stress. Surface quality has a very strong influence on the strength of the specimen. When cracks or porosity occur on the surface during specimen preparation, subsequent measurements may show appreciably lower flexural strength values29). Therefore, additional studies are needed to assess the effects of such factors. Last, clinical assessment is needed on issues that may arise during prostheses fabrication according to leucite glass-ceramic preparation methods (heat-pressed or CAD/CAM).

Future studies should conduct additional experiments to overcome the previously mentioned limitations, while focus should also be placed on studies related to the esthetic characteristics of ceramic prostheses.

Acknowledgements

This research was supported by the Cheongam College research grants in 2017.

References
  1. Yoshimura HN, Gonzaga CC, Cesar PF, and Miranda WG Jr: Relationship between elastic and mechanical properties of dental ceramics and their index of brittleness. Ceram Int 38: 4715-4722, 2012. https://doi.org/10.1016/j.ceramint.2012.02.056
    CrossRef
  2. Ritzberger C, Apel E, Holand W, Peschke A, and Rheinberger VM: Properties and clinical application of three types of dental glass-ceramics and ceramics for CAD-CAM technologies. Materials (Basel) 3: 3700-3713, 2010. https://doi.org/10.3390/ma3063700
    CrossRef
  3. Kim KB, and Kim JH: Influence of low temperature degradation on bond strength of yttria-stabilized tetragonal zirconia polycrystal core to veneering ceramic. J Dent Hyg Sci 14: 29-34, 2014.
  4. MacCulloch WT: Advances in dental ceramics. Br Dent J 124: 361-365, 1968.
    Pubmed
  5. McLean JW: Evolution of dental ceramics in the twentieth century. J Prosthet Dent 85: 61-66, 2001. https://doi.org/10.1067/mpr.2001.112545
    CrossRef
  6. Sakaguchi RL, and Powers JM: Craig's restorative dental materials. Elsevier Mosby, Philadelphia: 455-462, 2012.
    Pubmed
  7. Höland W, and Beall GH: Glass-ceramic technology. Wiley, Hoboken, 2012.
    CrossRef
  8. Krämer N, and Frankenberger R: Clinical performance of bonded leucite-reinforced glass ceramic inlays and onlays after eight years. Dent Mater 21: 262-271, 2005. https://doi.org/10.1016/j.dental.2004.03.009
    CrossRef
  9. Miyazaki T, Hotta Y, Kunii J, Kuriyama S, and Tamaki Y: A review of dental CAD/CAM current status and future perspectives from 20 years of experience. Dent Mater J 28: 44-56, 2009. https://doi.org/10.4012/dmj.28.44
    CrossRef
  10. Trost L, Stines S, and Burt L: Making informed decisions about incorporating a CAD/CAM system into dental practice. J Am Dent Assoc 137: 32S-36S, 2006. https://doi.org/10.14219/jada.archive.2006.0399
    CrossRef
  11. Chen X, Chadwick TC, Wilson RM, Hill RG, and Cattell MJ: Crystallization and flexural strength optimization of fine- grained leucite glass-ceramics for dentistry. Dent Mater 27: 1153-1161, 2011. https://doi.org/10.1016/j.dental.2011.08.009
    CrossRef
  12. Quinn GD, Giuseppetti AA, and Hoffman KH: Chipping fracture resistance of dental CAD/CAM restorative materials: part I--procedures and results. Dent Mater 30: e99-e111, 2014. https://doi.org/10.1016/j.dental.2014.02.010
    CrossRef
  13. Chen YM, Smales RJ, Yip KH, and Sung WJ: Translucency and biaxial flexural strength of four ceramic core materials. Dent Mater 24: 1506-1511, 2008. https://doi.org/10.1016/j.dental.2008.03.010
    CrossRef
  14. Anstis GR, Chantikul P, Lawn BR, and Marshall DB: A critical evaluation of indentation techniques for measuring fracture toughness: I, Direct crack measurements. J Am Ceram Soc 64: 533-538, 1981. https://doi.org/10.1111/j.1151-2916.1981.tb10320.x
    CrossRef
  15. Im YW, Jun SK, and Kim SC et al: Standardized test methods for mechanical properties of dental prosthetic/restorative materials and their applications. Korean J Dent Mater 42: 259-270, 2015. https://doi.org/10.14815/kjdm.2015.42.3.259
    CrossRef
  16. Alkadi L, and Ruse ND: Fracture toughness of two lithium disilicate dental glass ceramics. J Prosthet Dent 116: 591-596, 2016. https://doi.org/10.1016/j.prosdent.2016.02.009
    CrossRef
  17. Sin CH, Hwang SS, and Han GS: Shear bond strength of veneering ceramic and zirconia core according to the surface treatments. J Dent Hyg Sci 13: 487-492, 2013.
  18. Kim KB, and Kim JH: A study on the shear bond strength of veneering ceramics to the lithium disilicate (IPS e.max CAD) core. J Dent Hyg Sci 13: 290-295, 2013.
  19. Chen C, Trindade FZ, de Jaqer N, Kleverlaan CJ, and Feilzer AJ: The fracture resistance of a CAD/CAM Resin Nano Ceramic (RNC) and a CAD ceramic at different thicknesses. Dent Mater 30: 954-962, 2014. https://doi.org/10.1016/j.dental.2014.05.018
    CrossRef
  20. Song XF, and Yin L: Surface morphology and fracture in handpiece adjusting of a leucite-reinforced glass ceramic with coarse diamond burs. Mater Sci Eng: A 534: 193-202, 2012. https://doi.org/10.1016/j.msea.2011.11.058
    CrossRef
  21. Teixeira EC, Piascik JR, Stoner BR, and Thompson JY: Dynamic fatigue and strength characterization of three ceramic materials. J Mater Sci Mater Med 18: 1219-1224, 2007. https://doi.org/10.1007/s10856-007-0131-4
    CrossRef
  22. Zeng K, Odén A, and Rowcliffe D: Flexure tests on dental ceramics. Int J Prosthodont 9: 434-439, 1996.
    Pubmed
  23. Ban S, and Anusavice KJ: Influence of test method on failure stress of brittle dental materials. J Dent Res 69: 1791-1799, 1990. https://doi.org/10.1177/00220345900690120201
    CrossRef
  24. Passos SP, Nychka JA, Major P, Linke B, and Flores-Mir C: In vitro fracture toughness of commercial Y-TZP ceramics: a systematic review. J Prosthodont 24: 1-11, 2015. https://doi.org/10.1111/jopr.12179
    CrossRef
  25. Lin WS, Ercoli C, Feng C, and Morton D: The effect of core material, veneering porcelain, and fabrication technique on the biaxial flexural strength and weibull analysis of selected dental ceramics. J Prosthodont 21: 353-362, 2012. https://doi.org/10.1111/j.1532-849X.2012.00845.x
    CrossRef
  26. Bona AD, Anusavice KJ, and DeHoff PH: Weibull analysis and flexural strength of hot-pressed core and veneered ceramic structures. Dent Mater 19: 662-669, 2003. https://doi.org/10.1016/S0109-5641(03)00010-1
    CrossRef
  27. McCabe JF, and Carrick TE: A statistical approach to the mechanical testing of dental materials. Dent Mater 2: 139-142, 1986. https://doi.org/10.1016/S0109-5641(86)80021-5
    CrossRef
  28. Della Bona A, Mecholsky JJ Jr, and Anusavice KJ: Fracture behavior of lithia disilicate-and leucite-based ceramics. Dent Mater 20: 956-962, 2004. https://doi.org/10.1016/j.dental.2004.02.004
    CrossRef
  29. Harrer W, Danzer R, and Morrell R: Influence of surface defects on the biaxial strength of a silicon nitride ceramic: increase of strength by crack healing. J Eur Ceram Soc 32: 27-35, 2012. https://doi.org/10.1016/j.jeurceramsoc.2011.07.019
    CrossRef